Sign In | Join Free | My tjskl.org.cn
China HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD logo
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
You test us, We test equipment!
Active Member

4 Years

Home > Secondary Injection Test Set >

39.68lb Current Secondary Injection Test Set Multimode 6x150V Voltage Output

HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
Contact Now

39.68lb Current Secondary Injection Test Set Multimode 6x150V Voltage Output

Brand Name : HAOMAI

Model Number : RELAYSTAR-1600

Certification : ISO9001:2015, Type Test Report, Calibration Report

Place of Origin : China

MOQ : 1 set

Price : negotiation

Payment Terms : T/T

Supply Ability : 400 sets per month

Delivery Time : 5-10 working days

Packaging Details : Transport Case + Plywood Case

Product name : Relay Tester, Relay Test System, Protection Relay Test Set

6-phase current output : 6×0…40A

6-phase voltage output : 6×0…150V

AC Output Accuracy : ≤0.1%

Embedded IPC with LCD screen : Available

End-to-End Test : via built-in GPS

Contact Now

High Power 6-phase Secondary Injection Test Set

Model: RELAYSTAR-1600

The RELAYSTAR-1600 is 6-phase secondary injection test set for testing all generations and types of protection relays, which can output 6-phase current(6x0…40A) and 6-phase voltage (6x0…150V). Its powerful current source(6x0…40A, 6x300VA; 1x0…240A, 1x1000VA) is capable of testing high-burden electromechanical relays with very high power demands.

6-phase secondary injection test set RELAYSTAR-1600 can be synchronized to perform end-to-end testing with the test sets allocated in different substations through its in-built GPS.

The local software system of 6-phase secondary injection test set RELAYSTAR-1600 is designed based on Windows system. It can either be operated by embedded industrial PC with 10.4-inch TFT LCD screen or by test software running on a PC.

Main Features:

1) 6-phase current(6×40A) + 6-phase voltage(6×150V) output

2) Embedded industrial PC with 10.4-inch LCD screen

3) Both local test and PC remote test available

4) High performance linear power amplifier

5) In-built monitoring and recording

6) End to end test with in-built GPS

7) Intelligent self-protection

8) Abundant test modules

Technical Data

Current Generator

Setting range 6-phase AC(L-N) 6x0…40A
3-phase AC(L-N) 3x0…80A
1-phase AC(LL-LN) 1x0…240A
DC(L-N) 6x0…±20 A
Power 6-phase AC(L-N) 6x300VA at 40A
3-phase AC(L-N) 3x450VA at 80A
1-phase AC(LL-LN) 1x1000VA at 240A
DC(L-N) 6x120VA at 20A
Accuracy AC: ±1mA(≤0.2A), ≤0.1% (0.2~40A)
DC: ±5mA(0.2~0.5A), ≤0.2% (0.5~20A)
Resolution 1mA

Voltage Generator

Setting range 6-phase AC(L-N) 6x0…150V
3-phase AC(L-N) 3x0…300V
DC(L-N) 6x0…±175V
Power 6-phase AC(L-N) 6x80VA at 150V
3-phase AC(L-N) 3x100VA at 300V
DC(L-N) 6x80VA at 175V
Accuracy AC: ±2mV(0.2~2V), ≤0.1% (2~150V)
DC: ±10mV (0.5~5V), ≤0.2% (5~175V)
Resolution 1mV

Auxiliary DC Supply

Voltage range 110V/220V(max.1.5A)
Power max.165VA/330VA

Binary Inputs

Number 10
Input characteristics idle contact or potential-free contact
Threshold characteristics “0”:0~6V; “1”:12V~250V
Max. measuring time 999999.999s
Time accuracy ±1ms
Time resolution 1ms

Binary Outputs

Number 8
Type idle contact
Break capacity 250VAC/0.5A, 250VDC/0.2A

In-built Monitoring and Recording

Monitoring currents and voltage outputs
Recording analog outputs, binary inputs/outputs status
Mode real time monitoring, no external wiring is required
Recording length unlimited (until the internal memory is full)

General Generators

Frequency range: 0~1200Hz
accuracy:<1mHz(0~65Hz);<10mHz(65~450Hz);<20mHz(450~1200Hz)
resolution: 0.001Hz
Phase range: -360° ~+360°
accuracy: 0.1°
resolution: 0.01°
Harmonic superposition order: 2~24 times
distortion: ≤0.5%

Power Supply

Nominal input voltage customized (AC 220V/230V/120V±10%, 1-phase)
Nominal frequency 50/60 Hz
Rated current 10A at 230V / 12A at 115V
Connection standard AC socket (IEC 60320)

Environmental Conditions

Operation temperature 0 ... +50 °C (+32 ... +122 °F)
Storage temperature -25 ... +70 °C (-13 ... +158 °F)
Humidity range relative humidity 5 ... 95 %, non-condensing
Vibration IEC 60068-2-6(20m/s2 at 10 ... 150 Hz)

Miscellaneous

Weight 18kg(39.68 lb)
Dimensions (W x H x D, without handle) 420×360×210mm(16.54x14.17x8.27 in)
Connection port 2 USB2.0 ports, 1 Ethernet port

Safety Standards, Electromagnetic Compatibility

EMC The product adheres to the electromagnetic compatibility (EMC) Directive 2004/108/EC(CE conform)
IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3
Safety The product adheres to the low voltage Directive 2006/95/EC(CE conform).
IEC 61010-1

6-phase Secondary Injection Test Set RELAYSTAR-1600 is an excellent choice for testing and commissioning engineers to perform protection relay testing on site.


Product Tags:

39.68lb Secondary Injection Test Set

      

Multimode Secondary Injection Test Set

      

6x150V Current Injection Test Set

      
Quality 39.68lb Current Secondary Injection Test Set Multimode 6x150V Voltage Output for sale

39.68lb Current Secondary Injection Test Set Multimode 6x150V Voltage Output Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)